Choosing a suitable fan coil unit is an important part of designing an efficient heating and cooling system. In many modern residential, commercial and office buildings, available ceiling space is limited. This is why low-profile HVAC equipment can be a practical solution for projects where installation space matters. The slim ceiling fan coil manufactured by Ideh Pardazan Nakhl Mordab has been developed with a focus on compact dimensions, practical features and modern control capabilities. The company began its specialized production activities in 2019 after several years of experience and applied research in the building industry. The main purpose of this product line is to provide modern and functional solutions for heating and cooling systems while helping designers and installers deal with limited installation space. What Is a Slim Ceiling Fan Coil? A ceiling fan coil is a terminal HVAC unit designed to distribute conditioned air throughout an indoor space. It can be installed above suspended ceilings and connected to the building's heating and cooling system. The main advantage of a slim model is its reduced height. This particular fan coil has a height of only 130 mm, making it suitable for projects where the available ceiling void is limited. A compact body can simplify installation planning and help preserve the appearance of the interior space. It is particularly useful in apartments, offices, commercial units and other buildings where architectural details and ceiling height are important. Main Specifications of the Slim Ceiling Fan Coil The product is available in several capacity options to meet different project requirements. Capacity Height Width Length 200 130 mm 636 mm 443 mm 300 130 mm 636 mm 610 mm 400 130 mm 636 mm 946 mm 600 130 mm 636 mm 1228 mm All available models have a height of 130 mm, while their length changes according to the selected capacity. This range allows customers and HVAC professionals to select a model based on the requirements of the installation rather than using one fixed size for every project. 130 mm Height: An Important Installation Advantage One of the most noticeable features of this ceiling fan coil is its 130 mm height. In buildings with limited ceiling space, the dimensions of HVAC equipment can affect the installation process. A high-profile unit may require additional space and can make coordination with electrical systems, lighting, plumbing and other building services more complicated. A slim 130 mm design can provide more flexibility when planning the ceiling void. Before purchasing, however, the available installation space should always be measured carefully. The required space should include not only the dimensions of the fan coil itself but also the necessary clearance for connections, maintenance and airflow. DC Motor and Quiet Operation The unit is equipped with a DC motor, which is one of its key technical features. Motor selection can influence the operating characteristics of an HVAC unit, including noise level and energy consumption. For residential and office environments, reduced operating noise can be especially important. The slim ceiling fan coil is designed as a low-noise solution, making it suitable for environments where acoustic comfort is an important consideration. This can include: Residential apartments Office buildings Commercial spaces Hotels Educational environments Renovated buildings with limited ceiling space The final acoustic performance can depend on installation conditions, airflow settings, surrounding structures and other components of the HVAC system. Smart Control with Cyperus Another feature of this fan coil is its compatibility with the Cyperus application. The product can also be connected to a Cyperus wall thermostat, providing an additional option for controlling the unit. Modern HVAC systems increasingly use digital control solutions to make temperature management more convenient. Depending on the configuration of the project, app-based and wall-mounted controls can provide users with greater flexibility. For projects where modern control features are important, compatibility with the Cyperus ecosystem can be considered during the equipment selection process. Washable Filter for Easier Maintenance The fan coil is equipped with a washable filter. Filters play an important role in maintaining air quality inside the air-handling path and preventing dust and particles from accumulating on internal components. Regular filter inspection and cleaning can help maintain proper airflow and support consistent system operation. The exact cleaning interval depends on factors such as indoor air quality, usage frequency and the amount of dust in the environment. In locations with higher levels of dust, more frequent inspection may be necessary. Durable Galvanized Steel Body The body of the fan coil is made from galvanized material, providing a practical and durable structure for HVAC applications. The construction of the housing is important because the unit is typically installed in a concealed location where access may be more limited than with exposed equipment. A properly constructed housing can contribute to the overall durability of the product while also supporting easier integration into the building's mechanical system. Available Capacities: 200, 300, 400 and 600 The slim ceiling fan coil is offered in four capacity options: 200, 300, 400 and 600 Selecting the correct capacity should not be based only on the size of the room. Factors such as: Room dimensions Ceiling height Number of occupants Window area Building orientation Insulation Heat-generating equipment Local climate Desired indoor temperature can affect the required HVAC capacity. For this reason, professional load calculation is recommended before purchasing equipment for a complete project. How to Choose the Right Slim Ceiling Fan Coil? When buying a low-profile ceiling fan coil, several factors should be reviewed together. 1. Check the Available Installation Space Measure the ceiling void before selecting the model. The 130 mm product height should be considered together with the space required for piping, electrical connections and maintenance access. 2. Select the Appropriate Capacity Choose between the available 200, 300, 400 and 600 models based on the actual cooling and heating requirements of the space. 3. Consider Noise Requirements For bedrooms, offices and other quiet environments, the operating noise of the HVAC system can be For more information and free consultation, you can contact us. free consultation.